Escape door control unit
12 V DC; surface-mounted; signal green RAL 6032
Product description
To control electric locking systems in doors along escape routes; certified.
Escape door control module
- Emergency button lights up; features reusable, non-detachable, shatterproof protective cover
- Integrated door status indicator (green / red / yellow) signalling unlocked / locked / alarm status
- Emergency button sign (arrow pointing downwards)
- alarm signal and tampering contact;
- Key switch to control door
- With Euro profile half cylinder, including 3 keys
- Adjustable time intervals for temporary release, pre-alarm, alarm interval
- Monitoring of time door is open during temporary release.
- TS bus interface for parallel operation of visualisation software, panel and OPC server
- Connections: screw terminals
Scope of delivery
- 1 control terminal
- 1 emergency button sign
- 1 profile-half cylinder
- 1 operating manual
Rated voltage | 12 VDC SELV |
Output voltage | 12 V DC |
Power consumption | 0.2 A at 12 V |
Input operating voltage | 12 V DC |
Input voltage | 12 V DC |
Total power consumption | 0.2 A at 12 V |
Output current | for external consumers: max. 0.64 A (depending on the external power supply unit) |
Control | Yes, integrated |
Power supply | External power supply required |
Connection to panel, visualisation system, OPC server | Yes, model 1340–20 |
Configured centrally using FT Manager | No |
Stand-alone operation with I/O module | No |
Stand-alone operation (offline) | Yes |
Emergency switch | Yes |
Control element | Key switch with Euro profile cylinder; cam position 8 x 45°; 30.5 mm long |
Setting of times and functions | Via DIP switches |
Operating temperature range | 0 °C to +40 °C |
Class of protection | IP 20 |
Dimension | (HxWxD) 249x92x98 mm |
Inputs | E1: temporary release; E2: fire alarm system; E3: timer |
Outputs | A1: locked/unlocked; A2: collective alarm, contacts max. 24 V / 1 A |
Key switch on opposite side to direction of escape | Yes |
Certified in compliance with | EltVTR |