Switch cylinder N512

30 mm Diameter, laterally flattened to 22 mm -without key-

Product description

  • Power is supplied exclusively via the key (no battery in the cylinder)
  • Available as electronical version (V=)
  • Switch cylinder with one key withdrawal position at 0° and one scanning position at 60°
  • Brass cylinder housing components
  • Standard finish, satin nickel-plated (OF=MV)
  • Maintenance-free for up to 200,000 cycles
  • Dust and rain cover available (SUR=1) IP55
  • Optionally available for use in potentially-explosive atmospheres in Zone 1 (ATEX=II 2G Ex ib IIC T4 Gb)
  • Optionally available for permanent activation of the switch VAR=RASTUNG without key withdrawal on the scanning position
  • Two microswitches F4T 7-GP UL (Burgess) (VAC 48 V/ resistive load 5A, VAC 48 V/ inductive load 0.5 A)
  • Key rotation 60°
  • A rotation actuates a switch device (e.g. underground car parks, etc.).
  • Splash-proof IP54
  • Fixing with M30x1.5 housing nut

Scope of delivery

  • 1 switch cylinder
  • 1 housing nut M30 x 1.5 x 4
Variants that can be ordered
Article numberOF=AUS=V=VAR=
N512 MV 1E
Special equipment

Explosion protection

ATEX=DescriptionInfo
II 2G Ex ib IIC T4 GbLocking cylinders for Zone 1 hazardous areasper cylinder

Version

V2=AUS3=DescriptionInfo
ONLINECylinder with function "Online Open", frontal marking with symbol "@"per cylinder
SEQUENCECylinder with function "two-man rule", frontal marking with symbol "&"per cylinder
OHNE AUDITCylinder without events list, frontal marking with symbol "§"per cylinder

Special finish

OF=Area of applicationInfo
MC For profile and locking lever cylindersMatt, chrome plated
MG For profile and locking lever cylindersBrass, satin brushed
MP For profile and locking lever cylindersPolished brass
PC For profile and locking lever cylindersPolished chrome-plated

Special identification marking

DescriptionInfo
Special designation of your choice for the front of profile cylinders, 6 characters maximum (SBZ=)per cylinder

Dust and rain protection

SUR=Area of applicationInfo
1For special cylindersper cylinder

Variant

VAR=DescriptionArea of applicationInfo
RASTUNGPermanent activation of the switch without key withdrawal on the scanning positionFor switch cylinder .512per cylinder