DIN-direction | universal |
Electric strike voltage | 22-42 V AC/DC |
Adjustable keeper (FF, FaFix®) | Yes |
Monitoring contact (RR) | Yes |
Fail-locked | Yes |
Bi-directional diode | Yes |
Continuous duty | 22-26 V DC |
Rated resistance | 200 Ohm |
Switching capacity - monitoring contact | 24 V / 1 A |
Current consumption 24 V AC | 60 mA |
Current consumption 24 V DC | 120 mA |
Break-in resistance | 3750 N |
Height | 74 mm |
Width | 20,1 mm |
Depth | 25,5 mm |
FaFix® adjustment range | 3 mm |
Latch bolt engaging depth | 5,5 mm |
Operating temperature range | -15 °C to +40 °C |
Installation position | Vertical and horizontal |
Load cycles for in-plant test | 250000 |
Suitable for fire doors | No |
Max. preload 24 V AC | 200 N |
Max. preload 24 V DC (stabilised) | 50 N |
Max. preload 42 V DC (stabilised) | 200 N |