Electric strike 118---------D11
Without strike plate, 6-12 V AC/DC
Product description
Model with basic equipment.
Overview of Advantages
- Radius keeper, FaFix®, adjustable by 3 mm
- Voltage range
- Connection available to order as a connectible/pluggable option
- Compatible with current mortise locks
- Compatible with available striking plates
- Symmetrical design. DIN left/right as well as horizontal applicable
Scope of delivery
- 1 piece electric strike
| DIN direction | universal |
| Electric strike voltage | 6-12 V AC/DC |
| Adjustable keeper (FF, FaFix®) | Yes |
| Fail-locked | Yes |
| Rated resistance | 9 Ohm |
| Current consumption 6 V AC | 550 mA |
| Current consumption 6 V DC (stabilised) | 660 mA |
| Current consumption 12 V AC | 1100 mA |
| Current consumption 12 V DC (stabilised) | 1300 mA |
| Break-in resistance | 3750 N |
| Height | 66 mm |
| Width | 16 mm |
| Depth | 25.5 mm |
| FaFix® adjustment range | 3 mm |
| Latch bolt engaging depth | 5.5 mm |
| Operating temperature range | -15 °C to +40 °C |
| Installation position | Vertical and horizontal |
| Load cycles for in-plant test | 250000 |
| Suitable for fire doors | No |
| Max. preload 12 V DC (stabilised) | 60 N |
| Max. preload 6 V DC (stabilised) | 10 N |
| Max. preload 12 V AC | 160 N |
| Max. preload 6 V AC | 160 N |
| Max. latch preload DC (50% ripple) 12 V | 100 N |
| Max. latch preload DC (50% ripple) 6 V | 40 N |