Electric strike 143R
Product description
Model with monitoring contact as potential-free changeover contact. This is actuated by the latch bolt via a lever.
Can also be used as a high-security strike
Overview of Advantages
- Radius keeper, FaFix®, adjustable by 4 mm
- 12-24 Volt voltage range for AC and DC operation
- New connection technology, can be replugged
- Resistant to continuous current across the entire voltage range
- All models can be fitted as required (right/left/horizontally)
- Integrated surpressor diode
- Compatible with Model Range 142U
- Preload modes 400N or 800N can be set
Note
- Each version can be installed on the left, right, or horizontally. If space is limited, the terminal block can be fitted elsewhere on site.
| Adjustable keeper (FF, FaFix®) | Yes |
| Monitoring contact (RR) | Yes |
| Fail-locked | Yes |
| TVS diode | Yes |
| Changeable connection | Yes |
| Max. pre-load | 400 N / 800 N |
| Break-in resistance | 8000 N |
| Height | 79 mm |
| Width | 20 mm |
| Depth | 28 mm |
| FaFix® adjustment range | 4 mm |
| Latch bolt engaging depth | 6 mm |
| Operating temperature range | -15 °C to +40 °C |
| Continuous function load cycles | 200000 |
| Load cycles for in-plant test | 500000 |
| Installation position | Vertical and horizontal |
| Suitable for fire doors | Yes |
| Certified in compliance with | EN 14846:2008 |
| VdS class | Class B |
| Order number | Description |
|---|---|
| 143R--------Q34 | Without striking plate, 12/24V AC/DC DIN L |
| 143R--------Q35 | Without striking plate, 12/24 V AC/DC DIN R |