Panic function D, DIN direction reversible, panic side reversible
Product image 1
Overview of Advantages
DIN direction can be changed without tools
Panic side can be switched
New spring concept with strong compression springs for heavy handles
bolt stroke: single-turn 20 mm,
Certification according to EN 179
Certification according to EN 1125
Approved in accordance with prEN15685
Certification according to EN 1634-1 to 3
Intrusion resistance up to Class RC3 achievable in suitable door systems
Product description
These multi-point locks feature a door handle, panic door fitting or push bar on the inside of the door.
A door handle is also fitted on the outside of the door. When locked, the door cannot be opened from the outside, but can always be opened from the inside using the door handle, panic door fitting or push bar (panic function).
The square spindle (nut) is divided in panic function D. After the handle is operated from the inside, the door can also be opened automatically from the outside, i.e. the handle is coupled to the outside and rescue measures are not impeded. With this function, the door must always be locked again with the key to prevent it from being opened from the outside.
Area of Application
Security doors, escape route and fire doors
For new construction and renovation
Note
Not suitable for rotary knob cylinders
DIN direction can be changed (factory setting: DIN left)
Panic side can be switched
Only use bolt switch contact MSL 1886 on the frame side