Electric strike 19----------D11
Without strike plate, 6-12 V AC/DC
Product description
Model with basic equipment.
Overview of Advantages
- Can be mounted DIN right or left by turning over 180°
- A range of different slim-fit striking plates are available
- If DIN right is ordered, the reversible version (19A) is supplied
- If model 19 is combined with DIN direction 4 (position 15), the correct fitting position for the long part of the casing is upwards
| DIN direction | universal |
| Electric strike voltage | 6-12 V AC/DC |
| Adjustable keeper (FF, FaFix®) | Yes |
| Fail-locked | Yes |
| Input operating voltage tolerance range 6 V | wie angegeben |
| Input operating voltage tolerance range 12 V | wie angegeben |
| Nominal resistance 12 V | 8 Ohm |
| Rated resistance 6 V | 8 Ohm |
| Current consumption 12 V AC | 1100 mA |
| Current consumption 6 V AC | 550 mA |
| Current consumption DC (50% Residual ripple) 12 V | 1480 mA |
| Current consumption DC (50% Residual ripple) 6 V | 740 mA |
| Current consumption 12 V DC (stabilised) | 1560 mA |
| Current consumption 6 V DC (stabilised) | 780 mA |
| Break-in resistance | 3000 N |
| Height | 90 mm |
| Width | 16.5 mm |
| Depth | 28 mm |
| Operating temperature range | -15 °C to +40 °C |
| Material housing | Zinc die-cast |
| Material screw-on attachment | Brass |
| Max. preload 6 V AC | 150 N |
| Max. preload 12 V AC | 120 N |
| Max. latch preload DC (50% ripple) 6 V | 20 N |
| Max. latch preload DC (50% ripple) 12 V | 50 N |
| Max. preload 6 V DC (stabilised) | 10 N |
| Max. preload 12 V DC (stabilised) | 30 N |