Escape door control unit
For DIN rail; 12/24 V AC/DC; with safety relay module
Product description
To control electric locking systems in doors along escape routes in conjunction with applications without local emergency button, or applications with local emergency button and delayed release; certified.
Escape door control module
- Can be connected to door terminals and operating components
- Can be connected to locking components
- Adjustable time period for max. continuous release, delay in continuous release, temporary release, pre-alarm, alarm interval, guidance signal,
- Monitoring of time door is open during temporary release.
- With 4 inputs featuring adjustable parameters for:
- Control of locking and unlocking, temporary release, alarm acknowledgement via a potential-free contact in operating devices, such as card readers and keypad units.
- Temporary release using an access control system, or
- Emergency release via fire alarm system, or
- Priority locking via burglar alarm system, or
- Unlocking via timer, etc.
- With 4 relay outputs featuring adjustable parameters for:
- Door locked/unlocked, or
- Door open/closed, or
- Collective alarm, or individual alarm,
- Activation of electric strike/motorised lock/door automatics/arrestor system.
- TS bus interface for parameterisation using software (FT Manager) and networks for parallel operation of visual display software, panel and OPC server
- Security relay module to install applications without emergency button at door
- Connections: plug-in screw terminals
Rated voltage | 12-24 V DC SELV |
Output voltage | 12-24 V DC |
Output current | for external consumers: max. 2 A (depending on the external power supply unit) |
Power consumption | 0.2 A at 24V (including safety relay module) |
Control | Yes |
Power supply | External power supply required |
Certified in compliance with | EltVTR |
Connection to panel, visualisation system, OPC server | Yes |
Stand-alone operation with I/O module | Yes |
Stand-alone operation (offline) | Yes |
Emergency switch | No |
Control element | No, external operating unit/door terminal required |
Setting of times and functions | Via menu buttons and display on device using FT Manager (together with bus controller) |
Operating temperature range | -20 °C to +40 °C |
Class of protection | IP 30 |
Dimension | Control unit: WxHxD: 159x90x60mm; for installation on DIN rail (9 HP), safety relay module: WxHxD: 87x97x63mm or installation on DIN rail (5HP) |
Inputs | 4x; adjustable parameters |
Outputs | 4x; adjustable parameters, 30 V / 1 A switchover contact |
Key switch on opposite side to direction of escape | Yes |
Applications without local emergency button | Yes, in conjunction with central emergency button |
Applications featuring local emergency button with delayed release | Yes, in conjunction with central emergency button and FT-Manager |