ePED® Interface for locking
for installation in distribution box
Product description
System interfaces with safety functions for the connection of approved escape door locks. For mounting in distributor or junction boxes.
| Current consumption 24 V DC | 100 mA |
| Control function | Yes, Hi-O technology |
| Connection | 4-wire bus |
| Required power supply | 12 V (-15 %) to 24 V (+15 %) DC SELV; optimal voltage = 24 V DC |
| Operating temperature range | -10 °C – +55 °C |
| Area of application | For indoor use |
| Class of protection | IP30 (wenn vollständig montiert) |
| Installation | For mounting in distributor or junction boxes. |
| Dimension | 59 x 52 x 20 mm |
| Sabotage switch | No |
| Amount of bus addresses | 1 |
| Certified in compliance with | EltVTR; DIN EN 13637:2015 |
| Control | Yes, Hi-O technology |
| Time delay | Yes |