Panic function E, DIN direction reversible, double-leaf
Product image 1
Overview of Advantages
DIN direction can be changed without tools
New spring concept with strong compression springs for heavy handles
bolt stroke: single-turn 20 mm,
Certification according to EN 179
Certification according to EN 1125
Certification according to EN 1634-1 to 3
Intrusion resistance up to Class RC3 achievable in suitable door systems
Product description
These multi-point locks feature a door handle, panic door fitting or push bar on the inside of the door.
A door handle is also fitted on the outside of the door. When locked, the door cannot be opened from the outside, but can always be opened from the inside using the door handle, panic door fitting or push bar (panic function).
The square spindle (nut) is continuous with the panic function E. Depending on the architectural requirements, a bar or knob plate can be fitted on the outside. The door can be opened from the outside using the key via the changeover function. Can be used in combination with panic fixed leaf locking 50590/51590 in double-leaf doors.
Area of Application
Double-leaf security, escape route and fire doors
Note
Not suitable for rotary knob cylinders
DIN direction can be changed (factory setting: DIN left)
Only use bolt switch contact MSL 1886 on the frame side
Use in combination with inactive leaf lock 50590/51590 (not included in the scope of delivery).