Electric strike EX13823 ProFix 2
Without strike plate, 14.8 V DC
Product description
The EX138R electric strike is designed for use on doors in explosive atmospheres. It is equipped with monitoring contact as standard. The FaFix radius keeper can be adjusted by 3 mm. The connecting cable is 10 metres long.
Use for EX zones 1, 2, 21, 22 with an ignition energy of more than 3mJ. Ignition protection type "ib"
Labels:
Gas atmosphere: II 2G Ex ib IIB T4 Gb
Dust atmosphere: II 2D Ex ib IIIC T95 °C Db
Overview of Advantages
- For use in potentially explosive atmospheres, e.g. laboratories, chemical plants, mills, paint finishing plants
- Universal installation position, vertical and horizontal
- Holding force of 9,000 N
- Monitoring contact as standard
Scope of delivery
- Delivery without strike plate with connecting cable
Note
- The installation instructions must be observed!
- EX electric strikes may only be operated with EX-i accessories in accordance with the installation instructions.
Adjustable keeper (FF, FaFix®) | Yes |
Monitoring contact (RR) | Yes |
Diode (05) | Yes |
Fail-unlocked | Yes |
Power consumption 14.8 V DC | 123 mA |
Continuous duty | 14.8 V DC |
Certified in compliance with | EN 14846:2008 |
Load cycles for in-plant test | 250000 |
Installation position | Vertical and horizontal |
Operating temperature range | T4: –20 °C ≤ Ta ≤ + 50 ℃ |
Break-in resistance | 9000 N |
Length | 76 mm |
Connecting cable | 10 m |
Width | 20.5 mm |
FaFix® adjustment range | 3 mm |
Depth | 25.5 mm |
Latch bolt engaging depth | 6 mm |
| Order number | Product |
---|---|---|
EX1003-15----00 | Power supply 14.8 V, 160 mA | |
EX9170-------00 | EX-I switching amplifier type 9170/11-13-21s |