EX-I switching amplifier type 9170/11-13-21s

  • ArtNo: EX9170-------00
  • EAN: 4042203778474

Product description

EX-I switching amplifier EX9170-------00 has an input voltage of 110 to 230 V AC. This switching amplifier is only required if the monitoring contact is evaluated by the EX electric strike (door status OPEN or CLOSED, or to monitor the door release interval).

Overview of Advantages

  • Can be used up to SIL 2 (IEC/EN 61508)
  • Switch-off open-circuit and short-circuit monitoring, with message
  • Optional line fault transparency: The device signals field-side line faults directly to the control unit via the signal output

Note

  • Switching amplifier for evaluating the monitoring contact of the ATEX electric strike EX118 or EX138. Please observe the information in the installation and operating instructions and in the connection diagram.