Supplementary locking system 9338

Product description

Version with magnet bolt counterpart, with fail-unlocked strike 138TQ53

Overview of Advantages

  • Latch insertion on the door frame removed
  • Visually attractive, concealed installation, magnet bolt is retracted when door open
  • Low opening force due to weak keeper spring
  • No closing force due to magnet bolt
  • Quiet locking and unlocking
  • The supplementary locking system 9338 is designed as a supplementary locking system for versatile applications for the locking of doors
  • Example for other usage options: Office doors, laboratory doors, interlocks, wet cells in hospitals, special doors
  • Universal installation position, vertical and horizontal
  • Compatible with model 9334

Scope of delivery

  • Delivery as a complete set with striking plate or as a set without striking plate
Technical data
Adjustable keeper (FF, FaFix®)Yes
Fail-unlockedYes
Weak latch bolt springYes
Noise reductionYes
Input operating voltage± 10%
Current consumption 12 V DC235 mA
Current consumption 24 V DC150 mA
Break-in resistance3000 N
Height90 mm
Width20 mm
Depth23 mm
FaFix® adjustment range1 mm
Operating temperature range-15 °C to +40 °C
Installation positionVertical and horizontal
Load cycles for in-plant test220000
Bolt throw10 mm
material boltPlastic
Variants that can be ordered
Order number
Description
9338--------E91Without striking plate, 12 V DC
9338--------F91Without striking plate, 24 V DC