Supplementary locking system 9318
Without striking plate, 12-24V AC/DC
Product description
Version with magnet bolt counterpart, with fail-locked strike 118TQ53
Overview of Advantages
- Latch insertion on the door frame removed
- Visually attractive, concealed installation, magnet bolt is retracted when door open
- Low opening force due to weak keeper spring
- No closing force due to magnet bolt
- Quiet locking and unlocking
- The supplementary locking system 9318 is designed as a supplementary locking system for versatile applications for the locking of doors
- Example for other usage options: Office doors, laboratory doors, interlocks, wet cells in hospitals, special doors
- Universal installation position, vertical and horizontal
- Compatible with model 9314
Scope of delivery
- Delivery with magnetic bolt counterpart and fail-locked strike 118TQ53
DIN-direction | universal |
10-24 V AC/DC | |
Adjustable keeper (FF, FaFix®) | Yes |
Fail-locked | Yes |
Bi-directional diode | Yes |
Weak latch bolt spring | Yes |
Noise reduction | Yes |
Continuous duty | 11-13 |
Rated resistance | 43 Ohm |
Input operating voltage | ± 10 % |
Current consumption 12 V AC | 250 mA |
Current consumption 12 V DC (stabilised) | 280 mA |
Current consumption 24 V AC | 500 mA |
Current consumption 24 V DC (stabilised) | 560 mA |
Max. preload 12 V AC | 200 N |
Max. preload 12 V DC (stabilised) | 50 N |
Max. preload 24 V AC | >350 N |
Max. preload 24 V DC (stabilised) | 200 N |
Installation position | Vertical and horizontal |
Operating temperature range | -15 °C to +40 °C |
Break-in resistance | 3000 N |
FaFix® adjustment range | 1 mm |
Bolt throw | 10 mm |
Load cycles for in-plant test | 220000 |
material bolt | Plastic |
Height | 90 mm |
Width | 20 mm |