Electric strike 14S---------R15
Product description
Model with reversible design. The advantage lies in the fact that the connection also points upwards in the DIN-right version. This means the cable conduit is not near the deadbolt.
Overview of Advantages
- The minimum gap between the strike latch and casing lower surface enables DL and DR designs to be combined with locks which contain a minimum latch deadbolt clearance.
- For striking plates with minimum latch deadbolt clearance
- Suitable for all common striking plates
- Can be combined with striking plates with latch bolt guide (standard) without FaFix®
Scope of delivery
- 1 piece electric strike
DIN-direction | Right |
potential | 8-16 V AC/DC |
Fail-locked | Yes |
Rated resistance | 16,5 Ohm |
Current consumption AC 12 V | 500 mA |
Current consumption AC 16 V | 700 mA |
Current consumption AC 8 V | 350 mA |
Current consumption DC (50% Residual ripple) 12 V | 710 mA |
Current consumption DC (50% Residual ripple) 16 V | 940 mA |
Current consumption DC (50% Residual ripple) 8 V | 470 mA |
Current consumption DC (stabilized) 12 V | 725 mA |
Current consumption DC (stabilized) 16 V | 970 mA |
Current consumption DC (stabilized) 8 V | 485 mA |
Break-in resistance | 6500 N |
Height | 90 mm |
Width | 20,5 mm |
Depth | 28 mm |
Operating temperature range | -15 °C to +40 °C |
Installation position | Vertical |
Material housing | Zinc die-cast |
Latch material | Steel |
Max. latch preload AC operation 8 V | 110 N |
Max. latch preload AC operation 12 V | 80 N |
Max. latch preload AC operation 16 V | 100 N |
Max. keep pre-load DC (50% Residual ripple) 8 V | 10 N |
Max. latch preload DC (50% ripple) 12 V | 20 N |
Max. latch preload DC (50% ripple) 16 V | 40 N |
Max. latch preload DC (stabilised) 8 V | 10 N |
Max. latch preload DC (stabilised) 12 V | 10 N |
Max. latch preload DC (stabilised) 16 V | 20 N |