Electric strike 14ESFF------R15
Product description
Model with reversible design. The advantage lies in the fact that the connection also points upwards in the DIN right-hand version. This means the cable conduit is not near the deadbolt. With mechanical permanent unlocking in door strike latch. Adjustable FaFix latch which enables door strike latch to be aligned.
Overview of Advantages
- The minimum gap between the strike latch and casing lower surface enables DL and DR designs to be combined with locks which contain a minimum latch deadbolt clearance.
- For striking plates with minimum latch deadbolt clearance
- Suitable for all common striking plates
- Can be combined with striking plates with latch bolt guide (standard) without FaFix®
Scope of delivery
- 1 piece electric strike
DIN-direction | Right |
potential | 8-16 V AC/DC |
Adjustable keeper (FF, FaFix®) | Yes |
Mechanical unlocking (E) | Yes |
Fail-locked | Yes |
Rated resistance | 16,5 Ohm |
Current consumption AC 12 V | 500 mA |
Current consumption AC 16 V | 700 mA |
Current consumption AC 8 V | 350 mA |
Current consumption DC (50% Residual ripple) 12 V | 710 mA |
Current consumption DC (50% Residual ripple) 16 V | 940 mA |
Current consumption DC (50% Residual ripple) 8 V | 470 mA |
Current consumption DC (stabilized) 12 V | 725 mA |
Current consumption DC (stabilized) 16 V | 970 mA |
Current consumption DC (stabilized) 8 V | 485 mA |
Break-in resistance | 4000 N |
Height | 104 mm |
Width | 20,5 mm |
Depth | 28 mm |
Operating temperature range | -15 °C to +40 °C |
Installation position | Vertical |
Material housing | Zinc die-cast |
Latch material | Zinc die-cast |
Material surface-mounted attachment | Zinc die-cast |
Max. latch preload AC operation 8 V | 110 N |
Max. latch preload AC operation 12 V | 80 N |
Max. latch preload AC operation 16 V | 100 N |
Max. keep pre-load DC (50% Residual ripple) 8 V | 10 N |
Max. latch preload DC (50% ripple) 12 V | 20 N |
Max. latch preload DC (50% ripple) 16 V | 40 N |
Max. latch preload DC (stabilised) 8 V | 10 N |
Max. latch preload DC (stabilised) 12 V | 10 N |
Max. latch preload DC (stabilised) 16 V | 20 N |