Electric strike 14----------R11
Without face plate, 8-16 V AC/DC
Product description
Model with basic equipment.
Overview of Advantages
- Suitable for all common striking plates
- Can be combined with striking plates with latch bolt guide (standard) without FaFix®
- Due to 180° fitting, can be used DIN right and left
- Latch material: Steel
Scope of delivery
- 1 piece electric strike
Note
- Order code for version DIN right = 14A
DIN-direction | universal |
8-16 V AC/DC | |
Fail-locked | Yes |
Rated resistance | 16.5 Ohm |
Nominal resistance 12 V | 28 Ohm |
Current consumption 12 V AC | 500 mA |
Current consumption AC 16 V | 700 mA |
Current consumption AC 8 V | 350 mA |
Current consumption DC (50% Residual ripple) 12 V | 710 mA |
Current consumption DC (50% Residual ripple) 16 V | 940 mA |
Current consumption DC (50% Residual ripple) 8 V | 470 mA |
Current consumption 12 V DC (stabilised) | 725 mA |
Current consumption DC (stabilized) 16 V | 970 mA |
Current consumption DC (stabilized) 8 V | 485 mA |
Function | Arbeitsstrom |
Break-in resistance | 6500 N |
Height | 90 mm |
Width | 20 mm |
Depth | 28 mm |
Operating temperature range | -15 °C to +40 °C |
Installation position | Vertical and horizontal |
Max. Preload 8 V AC | 60 N |
Max. preload 12 V AC | 80 N |
Max. preload 16 V AC | 100 N |
Max. keep pre-load DC (50% Residual ripple) 8 V | 10 N |
Max. latch preload DC (50% ripple) 12 V | 20 N |
Max. latch preload DC (50% ripple) 16 V | 40 N |
Max. preload 8 V DC (stabilised) | 10 N |
Max. preload 12 V DC (stabilised) | 10 N |
Max. preload 16 V DC (stabilised) | 20 N |