Electric strike 3405RRF-----E91

Without striking plate, 12 V DC

  • ArtNo: 3405RRF-----E91
  • EAN: 4042203107526

Product description

Model with recovery diode for access control systems. Monitoring contact as potential-free changeover contact. This is actuated via a latch bolt lever. Door strike can be adjusted in the striking plate, thus making installation work a great deal easier.

Overview of Advantages

  • The universal strike in a solid design
  • Suitable for all common striking plates
  • Can be combined with striking plates with latch guide (model St.)
  • Reversible design = DIN right (DR=5)

Scope of delivery

  • 1 piece electric strike
Technical data
DIN-directionuniversal
12 V DC
Adjustable electric strike (F, Fix®)Yes
Monitoring contact (RR)Yes
Diode (05)Yes
Fail-unlockedYes
Rated operating voltage tolerance range± 1 V
Rated resistance61 Ohm
Current consumption DC (50% Residual ripple)180 mA
DC-power consumption (stabilised)195 mA
Break-in resistance5500 N
Height112 mm
Width20.5 mm
Depth28 mm
Operating temperature range-15 °C to +40 °C
Material housingZinc die-cast
Latch materialSteel
Max. keeper pre-load DC (50% residual ripple)10 N
Max. latch preload DC (stabilised)10 N