Electric strike 17E---------D11
Without strike plate, 6-12 V AC/DC
Product description
Model with mechanical unlocking.
Overview of Advantages
- Suitable for all common striking plates
- Due to 180° fitting, can be used DIN right and left
- Symmetrical design
Scope of delivery
- 1 piece electric strike
DIN-direction | universal |
6-12 V AC/DC | |
Adjustable keeper (FF, FaFix®) | Yes |
Mechanical unlocking (E) | Yes |
Fail-locked | Yes |
Nominal resistance 12 V | 9 Ohm |
Rated resistance 6 V | 9 Ohm |
Current consumption 12 V AC | 1100 mA |
Current consumption 6 V AC | 550 mA |
Current consumption DC (50% Residual ripple) 12 V | 1200 mA |
Current consumption DC (50% Residual ripple) 6 V | 630 mA |
Current consumption 12 V DC (stabilised) | 1300 mA |
Current consumption 6 V DC (stabilised) | 660 mA |
Break-in resistance | 3500 N |
Height | 75 mm |
Width | 20.5 mm |
Depth | 28 mm |
Operating temperature range | -15 °C to +40 °C |
Max. preload 6 V AC | 80 N |
Max. preload 12 V AC | 150 N |
Max. latch preload DC (50% ripple) 6 V | 80 N |
Max. latch preload DC (50% ripple) 12 V | 90 N |
Max. preload 6 V DC (stabilised) | 10 N |
Max. preload 12 V DC (stabilised) | 50 N |