Electric strike
Without striking plate, 22-42 V AC/DC
Product description
Model for magnetic latch locks, with weak latch bolt spring. With bipolar protective diode for access control systems.
Overview of Advantages
- Compatible with common magnet latch locks
- Radius keeper, FaFix®, adjustable by 3 mm
- Weak latch bolt spring
- Voltage range
- Compatible with existing ProFix® 2 striking plates
- Optimal latch ramps for gentle interaction with the latch bolt
- Symmetrical design. DIN left/right as well as horizontal applicable
Adjustable keeper (FF, FaFix®) | Yes |
Fail-locked | Yes |
Bi-directional diode | Yes |
Weak latch bolt spring | Yes |
Noise reduction | Yes |
Continuous duty | 22-26 V DC |
Rated resistance | 200 Ohm |
Current consumption 24 V AC | 60 mA |
Current consumption 24 V DC (stabilised) | 120 mA |
Max. preload 24 V AC | 200 N |
Max. preload 24 V DC (stabilised) | 50 N |
Max. preload 42 V DC (stabilised) | 200 N |
Break-in resistance | 3750 N |
Height | 66 mm |
Width | 20.1 mm |
Depth | 25.5 mm |
FaFix® adjustment range | 3 mm |
Latch bolt engaging depth | 5.5 mm |
Operating temperature range | -15 °C to +40 °C |
Installation position | Vertical and horizontal |
Load cycles for in-plant test | 250000 |
Suitable for fire doors | No |