Electric strike 914ZY-----02R14

8-16 V AC/DC, DIN left

  • ArtNo: 914ZY-----02R14
  • EAN: 4042203335950

Product description

Electric strike for glass doors with frame. The housing has a profile cylinder hole to enable emergency unlocking with a mechanical key in the event of a power failure. Due to the adjustable keeper, the glass door strike can be adjusted to the glass thickness. In the case of double-leaf all-glass doors, an electric strike must be installed in the door frame at the top for each leaf (not suitable for double acting swing doors). Models 914ZY are fastened with a safety bolt to ensure that the keeper is not fixed unintentionally when the door is open.

Overview of Advantages

  • Fail-locked (unlocked when energised)
  • Vertical and horizontal mounting possible
  • Adjustable to glass leaf thickness 9-12 mm (FaFix®)
  • With safety pin to prevent unintentional locking of the keeper

Scope of delivery

  • 1 electric strike with strike plate and profile cylinder housing, colour grey
Technical data
DIN-directionLeft
Adjustable keeper (FF, FaFix®)Yes
Fail-lockedYes
Input operating voltage tolerance range 8 Vwie angegeben
Input operating voltage tolerance range 12 Vwie angegeben
Rated resistance16.5 Ohm
Nominal resistance 12 V16 Ohm
Rated resistance 16 V16 Ohm
Rated resistance 8 V16 Ohm
current consumption350 mA
Current consumption AC 16 V700 mA
Current consumption AC 8 V350 mA
Current consumption DC (50% Residual ripple)470 mA
Current consumption DC (50% Residual ripple) 12 V710 mA
Current consumption DC (50% Residual ripple) 16 V940 mA
DC-power consumption (stabilised)485 mA
Current consumption 12 V DC (stabilised)725 mA
Current consumption DC (stabilized) 16 V970 mA
Current consumption DC (stabilized) 8 V485 mA
Glas door thickness9-12 mm
Break-in resistance3700 N
Height167 mm
Width24 mm
Depth31 mm
Operating temperature range-15 °C to +40 °C
Max. Preload 8 V AC80 N
Max. preload 12 V AC60 N
Max. preload 16 V AC60 N
Max. keep pre-load DC (50% Residual ripple) 8 V10 N
Max. latch preload DC (50% ripple) 12 V10 N
Max. latch preload DC (50% ripple) 16 V20 N
Max. preload 8 V DC (stabilised)10 N
Max. preload 12 V DC (stabilised)10 N
Max. preload 16 V DC (stabilised)10 N
Max. keeper pre-load DC (50% residual ripple)10 N
Max. latch preload DC (stabilised)10 N