Electric strike 914ZY-----02R15
8-16 V AC/DC, DIN right
Product description
Electric strike for glass doors with frame. The housing has a profile cylinder hole to enable emergency unlocking with a mechanical key in the event of a power failure. Due to the adjustable keeper, the glass door strike can be adjusted to the glass thickness. In the case of double-leaf all-glass doors, an electric strike must be installed in the door frame at the top for each leaf (not suitable for double acting swing doors). Models 914ZY are fastened with a safety bolt to ensure that the keeper is not fixed unintentionally when the door is open.
Overview of Advantages
- Fail-locked (unlocked when energised)
- Vertical and horizontal mounting possible
- Adjustable to glass leaf thickness 9-12 mm (FaFix®)
- With safety pin to prevent unintentional locking of the keeper
Scope of delivery
- 1 electric strike with strike plate and profile cylinder housing, colour grey
DIN-direction | Right |
Adjustable keeper (FF, FaFix®) | Yes |
Fail-locked | Yes |
Input operating voltage tolerance range 8 V | wie angegeben |
Input operating voltage tolerance range 12 V | wie angegeben |
Rated resistance | 16.5 Ohm |
Nominal resistance 12 V | 16 Ohm |
Rated resistance 16 V | 16 Ohm |
Rated resistance 8 V | 16 Ohm |
current consumption | 350 mA |
Current consumption AC 16 V | 700 mA |
Current consumption AC 8 V | 350 mA |
Current consumption DC (50% Residual ripple) | 470 mA |
Current consumption DC (50% Residual ripple) 12 V | 710 mA |
Current consumption DC (50% Residual ripple) 16 V | 940 mA |
DC-power consumption (stabilised) | 485 mA |
Current consumption 12 V DC (stabilised) | 725 mA |
Current consumption DC (stabilized) 16 V | 970 mA |
Current consumption DC (stabilized) 8 V | 485 mA |
Glas door thickness | 9-12 mm |
Break-in resistance | 3700 N |
Height | 167 mm |
Width | 24 mm |
Depth | 31 mm |
Operating temperature range | -15 °C to +40 °C |
Max. Preload 8 V AC | 80 N |
Max. preload 12 V AC | 60 N |
Max. preload 16 V AC | 60 N |
Max. keep pre-load DC (50% Residual ripple) 8 V | 10 N |
Max. latch preload DC (50% ripple) 12 V | 10 N |
Max. latch preload DC (50% ripple) 16 V | 20 N |
Max. preload 8 V DC (stabilised) | 10 N |
Max. preload 12 V DC (stabilised) | 10 N |
Max. preload 16 V DC (stabilised) | 10 N |
Max. latch preload AC | 80 N |
Max. keeper pre-load DC (50% residual ripple) | 10 N |
Max. latch preload DC (stabilised) | 10 N |